Описание

Amplifier Unit, DIN Rail Type
Model IB-1000
Type DIN rail mount
Main unit/Expansion unit Main unit
Head compatibility Yes
Display Display resolution 0.01 %, 0.1 %, 1 % (switchable)
Display range –99.999 to 99.999, –99.99 to 99.99, –99.9 to 99.9, –99 to 99 (switchable)
Digital display method Dual 7-segment display, Upper level: 5 red digits, Lower level: 5 green digits
Operation indicator Judgment indicator: 2-colour (green/red) LED (HI, GO, LO), Bank indicator: Green LED x 4, Laser emission warning indicator: Green LED, Others: Green LED x 8, red LED x 3
Analogue output voltage ±5 V, 1 to 5 V, 0 to 5 V Output impedance 100?*1
Analogue current output 4 to 20 mA Maximum load resistance 350 ?*1
Control Input Bank switch input, zero shift input Non-voltage input*2
Control input Zero-shift input
Laser emission stop input
Timing input
Reset input
Adjust input
Control output Judgment output (check output) Open collector (NPN/PNP switchable, N.O./N.C. switchable)*3
Power supply Power consumption 1,950 mW or less (at 30 V, 65 mA max.)*4
Rating Power voltage 10 to 30 VDC, including Ripple (P-P) 10 %, Class 2 or LPS
Environmental resistance Pollution degree 2
Ambient temperature -10 to +50 °C (No condensation or freezing)
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis
Material Case/Front panel: polycarbonate, keytop: polyacetal, cable: PVC
Weight Approx. 150 g
*1 ±5 V, 1 to 5 V, 0 to 5 V, or 4 - 20 mA should be selected. *2 The four external input wires are assigned with desired inputs. Rated no-voltage input: ON voltage 2 V or less, OFF current 0.05 mA or less Rated voltage input: Max. input rating 30 V or less, ON voltage 7.5 V or more, OFF current 0.05 mA or less *3 Rated NPN open collector output: Max. 50 mA/ch (20 mA/ch when expansion units are connected), 30 V or less, residual voltage 1 V or less Rated PNP open collector output: Max. 50 mA/ch (20 mA/ch when expansion units are connected), 30 V or less, residual voltage 2 V or less *4 The power consumption with slave units installed is the total of each amplifier unit's power consumption. Example: When using one master unit (IB-1000) with two slave units (IB-1050) (1,950 mW x 1) + (1,950 mW x 2) = 5,850 mW
''